Blood-Pressure-SPO2-PR-Monitor Echo80 Echo80 24 hour Automatic Ambulatory Blood Pressure, Sauerstoffsättigung des Blutes, Pulse Rate Medical Patientenmonitor
Blood-Pressure-SPO2-PR-Monitor Echo80
Echo80 24 hour Automatic Ambulatory Blood Pressure, Sauerstoffsättigung des Blutes, Pulse Rate Medical Patientenmonitor.
Introduction
Echo80 is a multifunctional Patientenmonitor, it can Monitor SPO2 and NIBP for a long time, and applies to the Krankenhaus wards or family daily health Versorgung.
Merkmale
kompakt and tragbar, easy to use
With Integrative SpO2 Sonde
Double working modes, Überwachung Funktion and 24 hours ambulatory NIBP measure Funktion can be flexibly set
NIBP and SpO2 can be monitored for a long time
NIBP and SpO2 data record for large capacity
With friendly user interface, the user can see list menu and review measure results
The device can Anzeige low power Informationen, alarm Informationen, error Informationen and time Informationen richly
Parameter alarm Funktion is Optional
Patient Informationen can be flexibly set
Case management Funktion. PC software can achieve data review, analysis measure results, seeing trend, printing reports and other Funktionen
Performance
NIBP
Measure Method: Oscillometry
Measure Mode: The upper arm measure
Measure Spektrum:
Erwachsene: SYS: 40mmHg~270mmHg
MAP:20mmHg~235mmHg
DIA: 10mmHg~215mmHg
pädiatrisch: SYS: 40mmHg~200mmHg
MAP: 20mmHg~165mmHg
DIA: 10mmHg~150mmHg
neonatal: SYS: 40mmHg~135mmHg
MAP: 20mmHg~110mmHg
DIA: 10mmHg~100mmHg
Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes
Resolution: 1mmHg
Accuracy: ±3mmHg
Increasing pressure mode: force pump increases pressure automatically
Reducing pressure mode: self-motion ladder reducing pressure mode
Alarm parameter: SYS / MAP / DIA
SPO2 (Options)
Measure Spektrum: 0%~100% (Resolution:1%)
Accuracy: 70-100%, ±2%, below 70% unspecified
Error in Weak Filling Condition:
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light:
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Pulse Rate (Options)
Measuring Spektrum: 0bpm~250bpm
Resolution: 1bpm
Accuracy: ±2 bpm or ±2% (select larger)
Anzeige: 2.4″ TFT color LCD
Power: DC 3V(Two „AA“, 1.5V Alkali Akku)
Produkt safety type: Type BF applied part (Internally powered, Defibrillation-proof)
Accessories
Cuff For Erwachsene
Integrative SpO2 Sonde
USB Data Line
Disk (PC software)
Pack
User manuell
Dimensions and Weight
Dimension: 128mm*69mm*36 mm
Weight: <350g
Software Advantage
- Up to 1000 patient cases can be edited and supervised.
- The time segment of dealing with the patient’s NIBP data is 48 hours.
- Connect the device by USB interface.
- Can upload patient Informationen data collection project and Herunterladen collection data.
- Can Anzeige scoop-shape trend graph, filling-type trend graph, histogram, pie chart, correlation line graph.
- Can edit every piece of data, and add annotation to it.
- Can edit basic Informationen,doctor’s advice Informationen, NIBP and SpO2 Status instruction, current medicine-taken Informationen, etc.
- unterstützen print preview and report printing.