Suchen…
    Startseite Unternehmen Nachrichten und Veranstaltungen Meditech Neonate Wrap Oximeter Sonde BCI Compatible
    Produktbibliothek

    Meditech Neonate Wrap Oximeter Sonde BCI Compatible

    Juni 2026 2 Min. Lesezeit

    Meditech Neonate Wrap Oximeter Sonde "BCI Compatible" Model: XXXX  by Meditech     XXXX SpO2 Pulsoximeter sensors are intended for kontinuierlich Überwachung of arterial oxygen saturation and pulse rate




    Meditech Neonate Wrap Oximeter Sonde „BCI Compatible“



    Model: XXXX  by Meditech

     

     

    XXXX SpO2 Pulsoximeter sensors are intended for kontinuierlich Überwachung of arterial oxygen saturation and pulse rate. The Pulsoximeter SpO2 Sonden are compatible with BCI and Meditech pulse Oxymeter with SpO2 connectors. 

    All material that comes into Kontakt with skin has passed the bio-compatibility test and can minimize the risk of skin allergies, cell cytotoxicity and stimulating.

    The XXX Pulsoximeter sensor Sonde is for adults, children, infants and neonates. The sensor can be applied to multi-sites, einschließlich fingers or toes. By wrapping the SpO2 Sonde around an infant’s finger or toe, it makes taking measurements a lot easier.

    Recommended positions: Use lateral side of foot for 2~9lbs (1~4kg) patients; use big toe for >7lb (3kg); use big toe or finger for >22lbs(10kg).

     

    Neonate Wrap Oximeter Sonde has two different types of connectors as shown in the diagram below 

    (left) and miniature D (right).

     

    Meditech SpO2 sensor (Wrap Pulsoximeter sensor)

    Warnung: For kontinuierlich Überwachung of a baby, the Überwachung must be performed under Erwachsene constant supervision. The Sonde is not a toy and the baby must not be allow to tangle up with the cable. This is especially true when the infant is capable of pulling things and can move his body around. Attach the Sonde to his feet; run the cable towards the end of the bed away from his body; keep the cable out of the baby’s view; secure the cable so that he cannot grab the cable or tangle himself.

    One approach is to secure the cable onto the bed sheet using safety pins, cover the cable with another bed-sheet leaving only a few inches out for attaching the Sonde to the baby, and then tuck the ends of the both bed sheets firmly and tightly under the mattress.

     

    Technical Spezifikationen

     

    • Measuring Spektrum for SPO2: 70-100%
    • SpO2 measurement accuracy: 90%–100%, ±1%; 70%–89%, ±2%; ≤70%, unspecified.
    • Storage temperature: -20°C to 50°C
    • Operation temperature: 5°C to 40°C
    • Relative humidity: 35% – 75%

     

    Teilen:

    Mehr aus Nachrichten und Veranstaltungen

    Alle Artikel ansehen
    Meditech-Bibliothek
    Meditech-Bibliothek Aug. 2026

    MD901F gegen MD901F-Android Fetal-Maternal-Monitor Vergleichstabelle

      Parameter MD901F MD901F-Android Type 12.1 inch 12.1 inch Standard Configuration FHR, TOCO, FM FHR, TOCO, FM, Touch Bildschirm, Networking…

    Weiterlesen 2 min
    Produktbibliothek
    Produktbibliothek Juni 2026

    iBreathe TOUCH Bildschirm SPIROMETER med inbyggd skrivare

    iBreathe TOUCH Bildschirm SPIROMETER med inbyggd skrivare Bärbar enhet för lungfunktionstestning Denna spirometer använder differentialtrycksteknik för att noggrant mäta över…

    Weiterlesen 2 min
    Produktbibliothek
    Produktbibliothek Juni 2026

    Wie werden AED-Pads hergestellt?

    How AED pads are manufactured The production of AED pads is a meticulous process involving several stages to ensure their…

    Weiterlesen 2 min